Gold Health Tech Gold Health Tech
search
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Total Knee Prosthesis

Reference: 614761Orthopedic Surgery
TypeTotal
SideLeft, Right

Associated tags

manage_search

Product fit review

Compare the available product information with your application and purchasing requirements.

description

Documentation request

Ask which specifications, manuals, or commercial documents are available for review.

support_agent

Supplier coordination

Discuss quantity, destination, packaging, and timing before confirming suitability.

Product information

Product summary

TKA fails to meet the same level of patient satisfaction as total hip replacement, as fewer knee patients are able to obtain a "forgotten joint" replacement. Studies indicate that approximately 20% of TKA patients are dissatisfied. Anterior knee pain and persistent swelling may be the consequence of excessive A/P motion. The knee is susceptible to A/P instability during the most frequently encountered functional activities in numerous P/S designs, as the stabilizing mechanism only engages after 70-80° of flexion.



SATISFACTION OF THE PATIENT

In a study in which patients had a conventional CR or PS in one knee and a medially stabilized device in the other, 76% preferred the knee with the "ball in socket" medial compartment. The following was reported by patients:



There is a greater sense of normal

It is more potent when ascending or descending stairs.It possesses exceptional single-leg weight bearing capabilities.The sensation of stability is enhanced during flexion and in general.

There are fewer clicks, pops, and clunks.The GMK Sphere is a total knee implant that is innovative and has been designed to provide maximum functional stability. Its purpose is to increase the satisfaction of TKA patients during activities of daily living and to reduce post-operative knee pain, as evidenced by the knee anatomy and kinematic studies conducted by Prof. Michael Freeman and Prof. Vera Pinskerova.The GMK Sphere is also available with SensiTiN, a ceramic-like coating that is intended to minimize the release of metal ions from the implant.input:
output:FEMININE COMPONENTThirteen sizes are available.

Anatomical: left and right

Cemented: deep pockets measuring 0.5 mm

Material: Cobalt-Chrome (Co-Cr-Mo ISO 5832-4)

Material: Cobalt-Chrome (Co-Cr-Mo ISO 5832-4) + SensiTiN coating

Continue your equipment review

Related products

Universal Operating Table Medical equipment

Universal Operating Table

OperationMechanical
ApplicationsUniversal, Neurosurgery, Ent, Radiology, Endoscopy, Dermatology, Urology, Laparoscopy, Ophthalmology, Orthopedy, Gynecology, Cardiology
FeaturesTilting, Ergonomic, Mobile, Radiolucent, Adjustable Height
ComponentsWith Legrest, With Armrest
Number Of Sections4-Section
MaterialStainless Steel

Available for specification review

Universal Operating Table Medical equipment

Universal Operating Table

OperationElectro-Hydraulic
ApplicationsUniversal, Gynecology, Orthopedy, Radiology, Ophthalmology, Ent, Neurosurgery, Urology, Cardiology, Laparoscopy, Dermatology, Endoscopy
FeaturesAdjustable Height, Mobile, Radiolucent, Ergonomic, Trendelenburg, Reverse Trendelenburg
ComponentsWith Legrest, With Remote Control, With Footswitch, With Rotating Column, With Eccentric Column

Available for specification review