Gold Health Tech Gold Health Tech
search
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Temperature Module For Multi-Parameter Monitor

Reference: 998952Monitoring
Measured ParameterTemperature, Pulse Rate, Spo2, Oxygen
ApplicationsClinical
Patient TypeAdult, Pediatric, Infant

Associated tags

manage_search

Product fit review

Compare the available product information with your application and purchasing requirements.

description

Documentation request

Ask which specifications, manuals, or commercial documents are available for review.

support_agent

Supplier coordination

Discuss quantity, destination, packaging, and timing before confirming suitability.

Product information

Product summary

1. Calculation outcome: The pulse rate and blood oxygen saturation are computed.2. Unit of measurement: blood oxygen saturation percentage, pulse rate in beats per minute (BPM);3. Serial communication: RS232 port, TTL level, 9600 baud rate.Performance Index1. Test range: pulse rate 30-250 beats per minute, blood oxygen saturation 0-100%;2. Resolution: pulse rate 1 bpm, blood oxygen saturation 1%;3. Accuracy of measurement: blood oxygen saturation is defined as 2% (70-100%), with no definition below 70%. Weak perfusion is greater than or equal to 0.1%, and the pulse rate is 3 BPM (30-250 BPM). Application Products / Accessories

Adult silicone spOâ‚‚ sensor, finger clip spOâ‚‚ sensorPediatric silicone spOâ‚‚ sensor, pediatric finger clip spOâ‚‚ sensorInfant disposable spOâ‚‚ sensor, finger clip spOâ‚‚ sensorNewborn disposable spOâ‚‚ sensor, newborn wrapped belt spOâ‚‚ sensorDisposable spOâ‚‚ sensor for adults and childreninput:
output:Benefits and Features of the Medlinket Oxygen Saturation ModuleHigh reliability and measurement accuracy, flexible installation mode, and compact size;Assist in the rapid and precise measurement of pulse rate and blood oxygen saturation.The influence of human body movement and weak perfusion measurement can be effectively restrained by utilizing enhanced digital signal processing technology.Ensure the clinical monitoring accuracy through an invasive clinical accuracy test (in comparison to a blood gas analyzer);Suitable for newborns, pediatrics, and adults;Low power consumption design with a single power supply that operates at 3.3V;The columnar schematic diagram of pulse intensity and plethysmographic wave can be viewed.A straightforward serial port connection that is effortless to integrate;

Continue your equipment review

Related products