Product summary

The Xenox C100 is a mobile c-arm that is both durable and dependable, with a price-performance ratio that is highly favorable. It features a user-friendly interface and intuitive software that is compatible with a variety of configurations.Specifications

Different models of the Xenox C100 are available, including those with a stationary or rotating anode tube and an image intensifier of 9" or 12" (exclusively for the rotating version).Horizontal length: 210 mmArc orbital movement: 135°WIG-WAG ±12.5°C-arm depth: 690 mm S.I.D.: 988 mm/980 mm/920 mm
Rotation of the arm about the horizontal axis by approximately 270°
5 kW of generator power in DC current (3.75 kW at 115 Vac)The generator operates at a frequency of 40 kHz.KV range: 40–120 kV

In continuous fluoroscopy, the maximum current is 8.0 mA.The maximum current in "SNAPSHOT" fluoroscopy is 30 mA.

The maximum current in the HCF with DFG (HRP) is 30 mA.The maximum current for pulsed fluorography with DFG (HRP) is 60 mA at 230 Vac and 45 mA at 115 Vac.

Max. current in digital graphy mode with DFG (HRP): 60 mA at 230 V; 45 mA at 115 VThe maximum current in radiography (hi-rad) is 35 mA at 115 Vac and 50 mA at 230 Vac.

The maximum current in radiography is 90 mAs at 115 Vac and 125 mAs at 230 Vac.

H.U. Safety is guaranteed after 28 minutes of fluoroscopy at 120 kV, 5 mA (600W). Max Fluoroscopy Time

A membrane keyboard with an alphanumeric touch-screen has a 5.7" LCD display that displays all operative parameters and error messages. Management of microprocessors. Rotation of the keyboard is limited to ± 60°. Functionality and Operating ModesMEMORY'S OPERATING MODALITIESCONTINUOS FLUOROSCOPY

PULSED FLUOROSCOPY (12/sec, 6/sec, 3/sec, 1/sec – without acquisition on hard disk)

DIGITAL SNAPSHOTFLUOROSCOPY mA (1/2): (range: 0.25-4 mA)RADIOGRAPHY: Two-point technique (kV and mAs)