Gold Health Tech Gold Health Tech
search
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Hemodialysis Catheter

Reference: 608967Intensive Care
ApplicationHemodialysis, Pressure Monitoring
Area Of The BodyBlood Vessel, Central Venous
Number Of LumenDouble-Lumen
Outer Diameter12 Fr
manage_search

Product fit review

Compare the available product information with your application and purchasing requirements.

description

Documentation request

Ask which specifications, manuals, or commercial documents are available for review.

support_agent

Supplier coordination

Discuss quantity, destination, packaging, and timing before confirming suitability.

Product information

Product summary

The ABLE® Haemodialysis Catheters (HDC) are single-use, sterile polyurethane catheters that are intended to establish a temporary blood connection between the patient and the dialysis machine for acute and short-term dialysis. They are accessible in a diverse array of French sizes, lumen configurations, and lengths. The multi lumen variants offer dedicated lumens for pressure monitoring, infusion therapy, and haemodialysis therapy. The HDC are packaged with the necessary components and accessories for insertion using the Seldinger technique.Ethylene oxide is employed to sterilize all products.



Purpose



The ABLE® Haemodialysis Catheters may be suitable for the following therapies:

- To provide temporary blood vessel access during haemodialysis treatment;
- Central venous pressure monitor;- Venous transfusion, whether continuous or discontinuous.input:
output:
The Catheter is surgically penetrated into three optional puncture points determined by the clinical requirement using the Seldinger Technique. The insertion sites are as follows:1. Internal jugular vein;2. Subclavian vein;3. Femoral vein.
The catheter may be inserted into the body for a maximum of 30 days. If the duration exceeds this limit, there is a risk of the catheter and tissue combining, which could lead to a severe incident.input:
output:Contraindicationsinput:
output:1. Infection or a cut wound in the vicinity of the puncture.2. Blood coagulation dysfunction.

3. During the anticoagulant treatment.

4. Symptoms of inadaptability to puncture operations, including pneumothorax and vein sclerosis.