Gold Health Tech Gold Health Tech
search
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Gc Chromatography System

Reference: 808368Physico-Chemical Analysis
Detector TypeFid, Ecd, Tcd, Fpd, Npd
Other CharacteristicsDouble-Column
TypeGc

Associated tags

manage_search

Product fit review

Compare the available product information with your application and purchasing requirements.

description

Documentation request

Ask which specifications, manuals, or commercial documents are available for review.

support_agent

Supplier coordination

Discuss quantity, destination, packaging, and timing before confirming suitability.

Product information

Product summary

1. The temperature, time, and gas flow are all indicated on the 5.7-inch LCD display.

2. Self-test, power protection, automatic ignition, keyboard lock, and antipower mutation interference function.

3. It is capable of automatically transferring data and upgrading programs by connecting to the Internet.

4. Outfitted with a flame ionization detector. Three detectors may be installed simultaneously.

5. It is possible to install a packed column and a capillary column simultaneously.
6. The double column compensation function is capable of effectively mitigating the impact of background noise and baseline drift.

7. The oven has a large capacity of 300*280*180mm and can accommodate two 0.32mm diameter capillary columns (each with a length of 80m).

8. Improved thermal insulation: the maximum temperature of the outer chamber is 40℃ when the oven, vaporizing chamber, and detector reach 300℃.

9. Data processing is facilitated by chromatography workstation software.oven



Temperature Range: RT to 450°C

Temperature Accuracy: ≤±0.1℃

16-phase temperature program

Maximum temperature and heating rate: 40℃ per minute.DetectorHydrogen Flame Ionization Detector (FID)Detection limit: ≤3×10-12g/s (Sample: n-hexadecane)Baseline drift: ≤1x10-13A/30minLinear range: greater than or equal to 107 input:
output:Thermal Conductivity Detector (TCD) (Optional)Sensitivity: >10000 mV/mg (Sample: n-hexadecane)Linear range: greater than or equal to 105 input:
output:Electron Capture Detector (ECD) (Optional) Detection limit: ≤1×10-14g/ml (Sample: n-hexadecane δ-666)

Linear range: 104 or greater input:
output:Flame Photometric Detector (FPD) (Optional)Detection limit: ≤2×10-11g/s for S ofthiophene and ≤1×10-12g/s for P ofmethyl parathion.Linear range (S): ≥103

Linear range (P): ≥104

Continue your equipment review