The BAB A7, an Alpha and Beta aerosol beacon, is specifically engineered for the monitoring of work stations during maintenance operations or the dismantling of work sites, where the absence of man-made noise is highly recommended.input:
output:The concentration of artificial Alpha and Beta radioactive aerosols is continuously monitored and measured by the BAB A7. An external probe may be included as an alternative for the purpose of measuring ambient Gamma radiation. In real time or remotely accessible, all data measured by the BAB A7 is displayed. Its algorithm enables the most effective compensation of Radon.input:
output:The beacon is offered in both stationary and mobile versions to accommodate the diverse requirements of its users, including the monitoring of construction sites or effluent. Versions that are compatible with Skylink and VD/VR communication standards are accessible.input:
output:Detector TypeDual silicon diode with a large area, 2 x 360 mm²input:
output:Range of energy

α: Ranging from 2 to 5.65 MeV

β: From 100 keV to 2 MeVinput:
output:Software-adjustable artificial α ROITemperature range:

Within the range of +5°C to +45°C (41°F to 113°F)Compliance with CEM regulations



EMI emission: EN 61000-6-4EMI immunity: Level 3 (EN 61000-4-3)input:
output:Range of measurement α: From 10^(-3) to 1.10^4 Bq/m³

β: From 10^(-2) to 1.10^4 Bq/m³input:
output:Display units: Bq/m³, µGy/hVolume of sampling: 6 m³/hPerformance compensating for the gamma background Compensation for radon The filter has a detection limit of 37 Bq/m3 for radon progenies activity, with a measurement time of 1 hour.

SDα is equivalent to 0.3 Bq/m3.

SDβ is equivalent to 2 Bq/m3.The protection index is as follows:IP 54input:
output:AlarmsAudible and visible alarm with two adjustable alarm thresholds for the type of radiation (α or β)