Gold Health Tech Gold Health Tech
search
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Electronic Laboratory Block Heater

Reference: 585165Sample Management
ConfigurationBenchtop
DisplayElectronic

Associated tags

manage_search

Product fit review

Compare the available product information with your application and purchasing requirements.

description

Documentation request

Ask which specifications, manuals, or commercial documents are available for review.

support_agent

Supplier coordination

Discuss quantity, destination, packaging, and timing before confirming suitability.

Product information

Product summary

A digital block heater provides precise temperature control in small vessels for one to four aluminum blocks. The temperature of the sample vessel can be directly controlled by the PT-1000 temperature sensor that is included. It is employed in conjunction with Greiner tubes, microplates, cuvettes, PCR tubes, and PCR strips. Melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations, and in situ hybridizations are all applications for which the block heater is well-suited.



• The temperature can be adjusted in steps up to 120°C.• Timer: Countdown can be set from 1 minute to 99 hours and 59 minutes.• Counter: The display of the heating time• A substantial quantity of blocks that are highly adaptable

• Display of error codes• Safety circuit that is permanently installed• Acoustic signal at the conclusion of the testData TechnicalBlock count: 1, 2, 3, or 4Heat output: 165 wattsThe temperature range for heating is as follows: room temperature +5°C to 120°C.Temperature display: YesDisplay resolution and adjustment: 1 k.Extension temperature sensor connection: CT (DIN12878)

PT 1000 variation;DIN EN 60751 Kl. A: ≤ ± (0.15 +0.002xITI) K

Temperature stability of the blocks at 37°C *: 0.2 ±°C

60°C * temperature stability within the blocks: 0.4 ±°C
Temperature Homogenity at 37°C *: 0.2 K

Temperature Homogenity at 60°C *: 0.4 K

Heating rate / Heat up time with external sensor *: 5 K/min
Material of the setup plate: Aluminum alloyDimensions of the setup plate are 96 x 76 mm.Fixed safety circuit: 150°CTimer: YesTime setting range: 1 to 5999 minutes * Measured in the IKA DBH Testing Block: For additional information, consult the manual.

Dimensions (W x H x D): 151 x 73 x 228 mm