Gold Health Tech Gold Health Tech
search
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Class I Glove Box

Reference: 623183Laboratory Infrastructure
ApplicationsLaboratory, Containment, Filling
Other CharacteristicsStainless Steel, Controlled Atmosphere, Vacuum
ClassClass I
ConfigurationBenchtop
manage_search

Product fit review

Compare the available product information with your application and purchasing requirements.

description

Documentation request

Ask which specifications, manuals, or commercial documents are available for review.

support_agent

Supplier coordination

Discuss quantity, destination, packaging, and timing before confirming suitability.

Product information

Product summary

Protector Controlled Atmosphere Glove Boxes offer a leak-proof environment that enables the handling of contamination-sensitive materials in an inert or vacuum environment. input:
output:Performance testing is conducted on fiberglass-lined models to ensure that they can maintain moisture levels as low as 2 ppm and oxygen levels as low as 0.4 ppm. Performance testing is conducted on stainless steel-lined models to ensure that they can maintain moisture levels as low as 1 ppm and oxygen levels as low as 0.2 ppm.input:
output:Do you require an ultrapure inert atmosphere? The new AtmosPure Re-Gen Gas Purifier accessory is compatible with all Protector Controlled Atmosphere Glove Boxes. This accessory has the capability to remove up to five liters of oxygen (13.500 ppm) and 660 grams of moisture (18 million ppm) at standard temperature and pressure (STP).input:
output: The following are the features:• The product was factory-tested for leaks using a mass spectrometer while pressurized with helium at a pressure of 5 inches of water gauge. No leaks that are detectable at a rate exceeding 1 x 10-6 ml/sec.input:
output:• Exceed the Class I atmosphere containment conditions for oxygen permeation by less than 1.67 ppm/min, as specified in the ISO 10648-2 test method.input:
output:• According to ISO 10648-2, oxygen permeation must be less than 0.3 ppm/min for fiberglass-lined models and less than 0.15 ppm/min for stainless steel-lined models.input:
output:• Four manual valves; two on the main chamber and two on the transfer chamber—are utilized for evacuating, filling, and additional control. With 3/8" compression fittings and 3/8" hose barbs.input:
output:• A low-profile, rear-mounted stainless steel pressure relief bubbler with a factory-installed design is located within ±6 inches of the water gauge.input:
output:• Two rear-mounted 3/4" OD compression fittings on the inlet and outlet for effortless connection to the optional AtmosPure Re-Gen Gas Purifier or other accessory drying train.