Gold Health Tech Gold Health Tech
search
Available for inquiry Specification-led inquiry

Medical equipment sourcing

Automatic Titrator

Reference: 1071760Physico-Chemical Analysis
TypeAutomatic
ApplicationsFor The Food Industry, Chloride, Sodium
manage_search

Product fit review

Compare the available product information with your application and purchasing requirements.

description

Documentation request

Ask which specifications, manuals, or commercial documents are available for review.

support_agent

Supplier coordination

Discuss quantity, destination, packaging, and timing before confirming suitability.

Product information

Product summary

The TitroLine® 5000 automatic titrator is a new device that integrates intelligence, a syringe burette, and a pH/mV meter. This intelligence executes the parameterization of the method on your behalf. The new Titrator TitroLine® 5000 is even more user-friendly and offers an even greater number of features than its predecessor.input:
output:The TitroLine® 5000 does not necessitate any additional training or advanced knowledge in order to achieve accurate and rapid results. Utilize the TitroLine® 5000 to accomplish the following: input:
output:
High-resolution pH/mV measurement input for pH-, ORP-, silver-, and additional mV electrodes.
Automatic temperature compensation is achieved through the use of Pt 1000 and NTC 30 temperature measurement inputs.

Standard methods for FOS/TAC, alkalinity, total acidity in beverages, chloride, and other parameters are preinstalled.

Dynamic and linear titration to equivalence pointsTitration to pH and mV-end pointsinput:
output:Examples of typical applications of environmental analysis and water/wastewater:pH-value, alkalinity (p+m-value), and FOS/TAC (refer to the titration curve and result screen for an illustration)Kjeldahl nitrogen totalPermanganat index and CODChloride in wastewaterTypical applications of food analysis include:Salt content (chloride, sodium chloride)The pH value and total acidity of wine, beverages, and other food products are calculated.

Vitamin C

Protein determination (Kjeldahl-nitrogen in milk and dairy products)The value of iodine and peroxideinput:
output:Precision - in accordance with DIN ISO 8655, part 3: precision: < 0.05%, accuracy: < 0.15 percent>




Certifications: ISO 8655, part 6, EMC: 2004/108/EG; safety EG- Directive 2006/95input:
output:Communications/Connectivity - 2 × USB (1 USB-A and 1 USB-B), 2 × RS-232-Cinput:
output:Visible1/4 VGA TFT graphic color display with 320 x 240 pixels, measuring 3.5 inches

Continue your equipment review

Related products