2 Bipolar Channels Electromyograph
| Number Of Channels | 2 Bipolar Channels, 20 Unipolar Channels |
| Other Characteristics | With Evoked Potential Monitoring |
Description
NeMus 2NeMus 2 is a system for neurological diagnosis that is both innovative and polyvalent, and it seamlessly integrates all of the instrumental capabilities of a comprehensive neurophysiological laboratory.input:
output:In order to broaden its intended application to the four applications of EMG/NCS, EP, EEG, and ICU, NeMus 2, which was born as a natural evolution of the NeMus system, integrates the recording section with an acquisition head-box of monopolar channels. A single device is required for multimodal applications.The following is a list of the most frequently asked questions:Primary attributes
Two bipolar high-dynamic recording channels for EMG/NCS, which can be upgraded to four channels.
20 monopolar channels for all types of EP/ERP
22 channels for the acquisition of EEG/VEEG
High signal quality (high CMRR, high sensitivity for a large dynamic, low noise)WIDE BAND FOR EEG AND EMG CHANNELSFive-channel electrical stimulator integrated
Integrated visual and acoustic stimulators for all types of EP
Two trigger channels must be connected to external stimulators, such as TMS equipment.Galileo Suite software packages that are currently accessibleEMG/NCS
EP
ERPEEG
ICUClinical Applications on Galileo Suite
Clinical EEG/Video EEG
Cerebral Death Assessment and EEG in the ICU
aEEG/CFM
EMG and NCS
Evoked Potentials
Cognitive Studies and Event-Related Potentials
Neurophysiological Monitoring (EEG/SEP) in the ICU
Shipping & Delivery
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
10-Channel Eeg System
Compact Patient Monitor
| Other Characteristics | Continuous, Non-Invasive |
| Measured Parameter | Ecg, Resp, Temp, Heart Rate, Etco2, Nibp, Ibp, Cardiac Output, Eeg, Spo2 |
| Configuration | Portable, Compact |
| Applications | Intensive Care, Clinical |
| Technology | Pulse Wave Analysis |
| Options And Accessories | Wifi, With Touchscreen, With Built-In Printer, Usb |